Air Toilet – Flush cycle too longFlush cycle too longAdjust timing valve (sometimes referred to as Bleed-Off Plug in the manuals) – Loosen by a quarter turn and check flush cycle after each turn until the cycle is between 4-6 secondsTiming valve could be blockedRemove & clean/replace